Evaluation of an Improved Technique for Automated Center Lumen Line Definition in Cardiovascular Image Data

H. A. F. Gratama van Andel, E. Meijering, A. van der Lugt, H. A. Vrooman, C. de MonyƩ, R. Stokking

European Radiology, vol. 16, no. 2, February 2006, pp. 391–398

DOI PubMed

A new method, called VAMPIRE, was developed for automated definition of a center lumen line in vessels in cardiovascular image data based on improved detection of vessel-like structures. Subsequently, a multi-observer evaluation study was conducted involving 40 tracings in clinical CTA data of carotid arteries to compare VAMPIRE with an established technique. This comparison showed that VAMPIRE yields considerably more successful tracings and improved handling of stenosis, calcifications, multiple vessels, and nearby bone structures. We conclude that VAMPIRE is highly suitable for automated definition of center lumen lines in vessels in cardiovascular image data.


Copyright © 2006 the authors. Published version © 2006 Springer. Personal use of this material is permitted. However, permission to reprint or republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works, must be obtained from the copyright holder.