Erik Meijering PhD FIEEE

A Variational Model for Level-Set Based Cell Tracking in Time-Lapse Fluorescence Microscopy Images

O. Dzyubachyk, W. Niessen, E. Meijering

IEEE International Symposium on Biomedical Imaging (ISBI 2007)
Held in Arlington, VA, USA, April 12–15, 2007
Proceedings edited by J. Fessler and T. Denney
Institute of Electrical and Electronics Engineers, April 2007, pp. 97–100

PDF DOI Update

Quantifying the motion and deformation of large numbers of cells through image sequences obtained with fluorescence microscopy is a recurrent task in many biological studies. Automated segmentation and tracking methods are increasingly needed to be able to analyze the large amounts of image data acquired for such studies. In addition, automated techniques have the possibility to improve sensitivity, objectivity, and reproducibility compared to human observers. Recent efforts in this area have revealed the potential of model evolution methods, notably active contours and level sets, for this purpose. One of the disadvantages of such methods is their sensitivity to parameter settings. In this paper we propose a variational model for level-set based cell tracking which involves less parameters with more intuitive meaning compared to previous approaches. The improved performance is demonstrated with experimental results on real time-lapse fluorescence microscopy image data.


Copyright © 2007 the authors. Published version © 2007 Institute of Electrical and Electronics Engineers. Personal use of this material is permitted. However, permission to reprint or republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works, must be obtained from the copyright holder.