Serial Assessment of Atherosclerotic Carotid Plaque Volume and Plaque Component Volumes With Multidetector Computed Tomography Angiography

T. T. de Weert, S. E. Cretier, H. Cakir, E. Meijering, D. W. J. Dippel, A. van der Lugt

Annual Meeting of the Radiological Society of the Netherlands (NVvR 2006)
Held in Kaatsheuvel, Netherlands, November 17, 2006

Update

Purpose: To assess the potential of multidetector computed tomography angiography (MD-CTA) in the measurement of progression of atherosclerotic carotid plaque volume and plaque component (calcifications, fibrous tissue and lipid) volumes.

Methods and Materials: Atherosclerotic plaque volume and plaque component volumes at the symptomatic and asymptomatic carotid artery were measured in the MD-CTA images of 6 patients with a TIA and minor stroke at base line and at follow up (12, 12, 12, 16, 20 and 34 months). Plaque volumes were assessed with a custom-made software tool by manual drawing of the outer-contour of the carotid artery bifurcation. Luminal boundary was based on a Hounsfield-Unit (HU) threshold. Within the plaque volume the contribution of different components was measured by counting the number of voxels within defined ranges of HU-values (calcification >130 HU, fibrous tissue 60–130 HU, lipid <60 HU) validated in a previous study. Finally, differences in plaque volume and plaque component volumes between base line and follow up were assessed.

Results: At base line the plaque volume in the 12 arteries was 942 ± 373 mm3 and the calcified, fibrous tissue and lipid volumes were 136 ± 132 mm3, 600 ± 297 mm3 and 207 ± 141 mm3, respectively. At follow up, atherosclerotic plaque volume and plaque component volumes showed progression in each carotid artery. The atherosclerotic plaque volume was 1616 ± 794 mm3 and the calcified, fibrous tissue and lipid volumes were 245 ± 268 mm3, 917 ± 387 mm3 and 454 ± 295 mm3, respectively. A significant (p < 0.05) increase in plaque volume was found (674 ± 380 mm3); the changes in calcified, fibrous tissue and lipid volumes were not significant.

Conclusions: Atherosclerotic carotid plaque volume and plaque component volumes can be assessed with MD-CTA. Follow-up studies revealed an increase of atherosclerotic plaque volume.

Clinical Relevance/Application: Progression of atherosclerotic carotid plaque volume and a change in plaque composition can be monitored in vivo with MD-CTA.


Copyright © 2006 the authors. Published version © 2006 Nederlandse Vereniging voor Radiologie. Personal use of this material is permitted. However, permission to reprint or republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works, must be obtained from the copyright holder.