Studying Molecular Processes In-Vivo: A Framework for Quantifying Variability in Molecular MRI

E. Plenge, G. Kotek, J. Guenoun, G. Doeswijk, G. P. Krestin, W. J. Niessen, E. Meijering, M. Bernsen

European Molecular Imaging Meeting (EMIM 2010)
Held in Warsaw, Poland, May 26–29, 2010


Introduction: Reliable quantitative characterization of cellular and molecular processes in-vivo is dependent on consistent image data acquisition and analysis. To unambiguously detect biological changes over time, these changes should exceed those attributed to imaging artifacts and inconsistencies. The aim of this work is to establish a framework for quantifying the variability inherent to molecular magnetic resonance imaging (mMRI) protocols.

Methods: The framework is based on the analysis of a series of imaging examinations with identical scanning parameters, assuming that no biological changes occur within the time frame of the imaging experiment. Imaging data are rigidly aligned using image registration, variance maps and variance histograms are computed, and inter- and intra-observer variability of image analysis tasks such as manual outlining are assessed. To demonstrate the efficacy of the framework we have compared the variability of two different acquisition protocols in the challenging environment of a rodent heart. SPIO labeled stem cells were injected into the myocardium of a rat and cardiac MRI was performed. Without moving the anesthetized rat at any point, seven 3D non-triggered images and seven 2D cine sequences were acquired intermittently to capture inevitable changes due to breathing, coil-heating, et cetera, in both data sets. Three experts manually segmented the cell cluster in each slice/frame of each 3D/cine sequence. The inter- and intra-observer variability was quantified by a similarity index (SI).

Results: The variance distribution of the datasets due to imaging inconsistencies and the inter- and intra-observer variability of the expert segmentations were assessed both qualitatively and quantitatively. According to the SI, the variability of cell cluster segmentations between observers was 0.70 for the 3D protocol and 0.79 for the 2D cine protocol, while within observers it was found to be 0.56 for the 3D protocol and 0.64 for the 2D cine protocol.

Conclusions: The proposed framework allows objective quantification of the variability inherent to mMRI protocols. The results suggest a lower limit of changes that can be detected when studying biological processes with a certain mMRI protocol.


Copyright © 2010 the authors. Published version © 2010 European Society for Molecular Imaging. Personal use of this material is permitted. However, permission to reprint or republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works, must be obtained from the copyright holder.