Super-Resolution Reconstruction of Whole-Body MRI Mouse Data
A. Khmelinskii, E. Plenge, P. Kok, D. Poot, O. Dzyubachyk, C. P. Botha, E. Suidgeest, W. Niessen, L. van der Weerd, E. Meijering, B. P. F. Lelieveldt
Hot Topics in Molecular Imaging (TOPIM 2012)
Held in Les Houches, France, April 15–20, 2012
Introduction: Super-Resolution Reconstruction (SRR) is the process of producing a high-resolution (HR) image from a sequence of low-resolution (LR) images, where each LR image transforms and samples the HR scene in a distinct fashion. However, visualization of HR data is often computationally heavy and the time necessary to reconstruct large volumes (whole-body mice datasets) can be large. To overcome this disadvantage, we make use of recent progress in the areas of articulated atlas-based segmentation of whole-body small animal data and MRI SRR. We present a novel approach for producing HR, localized isotropic volumes-of-interest (VOIs) in whole-body mouse MRI. This enables interactive HR visualization and exploration of anatomical structures in MRI. Using the presented method, from a global LR image the user can interactively zoom-in on any VOI.
Methods: One post-mortem C57BL6, 6 month old, male mouse was scanned on a 7T Bruker Pharmascan system using a fast recovery FSE sequence. TR was 6648 ms, TE was 33 ms, with Navg = 1 and NSP = 1. The 2D slice stack consisted of 64 slices, with a FOV of 50 × 32 mm, and a resulting resolution of 0.125 × 0.125 × 0.5 mm. The scan time per stack was 213 s. The slice stack was rotated 23 times in uniform increments of 180/24 degrees. To segment the mouse, a semi-automated atlas-based bone approximation method was applied on one of the LR datasets. Next, the Articulated Planar Reformation (APR) algorithm was applied to reformat the data into segments specified by the atlas, thus mapping it to the standardized atlas space. Now, the user can interactively select any VOI for a subsequent SRR. The data needed to reconstruct the VOI at the requested level of resolution is collected from a database of LR images. For the purpose of both effective and efficient reconstruction, our method employs Tikhonov regularization using the L2-norm of the second order derivative of the reconstruction as the regularization term, together with an affine transformation scheme that minimizes aliasing and spectral distortions.
Results: The proposed local SRR approach was tested for each segmented bone, using an increasing number of LR images. The SRR times for each bone experiment were compared with SRR times for the whole-body. SRR time scales approximately linearly with the size of the LR dataset. Where the entire mouse requires hours to reconstruct, the VOI can be reconstructed within minutes. The sample axial slices demonstrate that the quality of the reconstructions clearly improves when an increasing number of LR images is used. In agreement with the results of the quantitative experiments, it can be observed that the quality improvement is substantial going from 2 to 8 LR images, while a smaller effect is seen when going from 12 to 24 LR images.
Conclusions: This method allows overcoming the time and memory limitations of the SRR technique. However, the mean time for the best quality SRR result, using 12 LR images, is still in the order of minutes. Since the results presented here were acquired on a MATLAB implementation, the computation times will considerably decrease by re-implementing the algorithm in a C/C++ and GPU programming environment combination.
Copyright © 2012 the authors. Published version © 2012 European Society for Molecular Imaging. Personal use of this material is permitted. However, permission to reprint or republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works, must be obtained from the copyright holder.