Deep Learning Methods for Automated Measurement of Lower Leg Muscle Volumes From MRI Scans of Children With and Without Cerebral Palsy

J. Zhu, B. Bolsterlee, B. V. Y. Chow, C. Cai, R. D. Herbert, Y. Song, E. Meijering

Australasian Biomechanics Conference (ABC 2021)
Held in Adelaide, SA, Australia, December 6–7, 2021

Update

Introduction: Cerebral palsy is a condition that is known to affect muscle growth. The most detailed investigations of muscle growth use magnetic resonance imaging (MRI). Measurement of muscle volumes from MRI scans currently requires manual segmentation of muscles, which is time-consuming and subjective. In this study, we test two deep learning models for automated measurement of muscle volumes from MRI scans of children with and without cerebral palsy.

Method: Using a 3T MRI scanner (Philips Ingenia CX), T1-weighted MRI scans were obtained from the lower legs of 20 children, 6 of whom have cerebral palsy. Participants ranged in age from 5 to 15 years, weight from 17 to 77 kg, and height from 108 to 172 cm. One researcher segmented a total of 11 muscles and two bones (tibia and fibula) on all 20 scans. Some of the smaller muscles were grouped into one segmentation label. Five scans were also segmented by another researcher to determine inter-rater performance.

A 2D UNet and a H-DenseUNet (a hybrid network that combines 2D and 3D features) were trained to automatically segment muscles and bones from these MRI scans. Five-fold cross-validation was used to compare performance between models. Performance was evaluated by the volume error, calculated as the absolute difference in label volume between automated and manual segmentations. The volume error of a scan is the median error of all labels.

Results: The H-DenseUNet and the UNet gave plausible segmentations of most muscles on most scans. The median volume error across scans was 2.6 cm3 for both models, which was slightly lower than the median inter-rater performance of 3.3 cm3. Performance varied between muscles. Expressed as a percentage of mean muscle volume, median errors were 5.1% for the HDenseUNet and 7.3% for the UNet.

Conclusions: Deep learning can be used for automated measurements of muscle volumes from MRI scans of children's lower legs, with typical errors similar to the difference between two manual segmentations. Further analyses showed that performance was similar between scans of typically developing children and children with cerebral palsy. The automated methods will enable large-scale investigations of typical muscle growth and disordered muscle growth in children with cerebral palsy.


Copyright © 2021 the authors. Published version © 2021 Australian and New Zealand Society of Biomechanics. Personal use of this material is permitted. However, permission to reprint or republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works, must be obtained from the copyright holder.