Beyond Doppler: Valve Kinematics Enables Rapid, Single-View Assessment of Aortic Stenosis Severity
F. Mohammed, T. Meredith, A. Pomeroy, H. Adams, T. P. Moran, S. Barbieri, E. Meijering, D. Roy, J. Kovacic, C. Hayward, D. Muller, M. P. Feneley, M. Namasivayam
New York Valves (NY Valves 2026)
Held in New York, NY, USA, June 24–26, 2026
Background: Aortic valve leaflet motion is a fundamental determinant of aortic stenosis (AS) severity, yet it is not directly quantified in conventional echocardiographic assessment. Valve kinematics integrates velocity and acceleration along with displacement to provide a physiologically grounded framework for characterizing leaflet mechanics and identifying distinct phenotypes of AS.
Objectives: To assess whether the valve kinematics framework provides incremental value over conventional echocardiographic measures in the evaluation of AS.
Methods: A retrospective cohort of 223 echocardiograms spanning the full spectrum of AS was analysed (65 no AS, 69 moderate, 89 severe). Using only the parasternal long-axis (PLAX) view, our computer vision algorithm was extended to quantify valve kinematics by incorporating angular velocity and acceleration with all metrics indexed to transaortic volumetric flow to derive flow-adjusted metrics. Machine learning models were applied for severity classification, with performance evaluated using accuracy and area under the receiver operating characteristic curve (AUC). External validation was performed in an independent cohort of 270 patients (96 no AS, 73 moderate, 101 severe) to assess generalizability.
Results: Logistic regression achieved the highest performance for AS severity classification on the internal cohort with an accuracy of 84.37% and AUC of 0.96. On the external dataset, it maintained strong results with 85.24% accuracy and AUC of 0.94, demonstrating robust generalizability across patient populations.
Conclusions: Valve kinematics-based leaflet motion analysis from PLAX echocardiography enhances distinct phenotyping of AS severity without Doppler measurements. Its strong and consistent performance on both internal and external datasets highlights its potential as a rapid, generalizable tool for improving clinical workflows.
Copyright © 2026 the authors. Personal use of this material is permitted. However, permission to reprint or republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works, must be obtained from the copyright holder.