Evaluation of a New Method for Automated Center Lumen Line Detection in Multi-Slice CTA Data of Carotid Arteries
H. A. F. Gratama van Andel, E. Meijering, A. van der Lugt, H. A. Vrooman, R. Stokking
Annual Meeting of the Radiological Society of the Netherlands (NVvR 2003)
Held in Noordwijkerhout, Netherlands, October 2–3, 2003
Purpose: Accurate and automated quantitative analysis of vessels is crucial in clinical decision making. We have developed and evaluated an automated center lumen line (CLL) detection method, which provides the basis for measurements on carotid arteries, most notably degree of stenosis.
Methods and Materials: The detection of vessels in automated techniques is often regarded as a problem of multi-scale line and orientation analysis. By analyzing the second-order derivatives (ridges) of an image, linear structures can be enhanced and non-linear structures suppressed. Ridge detection in combination with minimal-cost path-search algorithms forms the basis of recently developed automated techniques for CLL detection. These techniques are hampered by calcifications, occlusions, and nearby bones, which frequently results in a tracing of the CLL partly outside the vessel of interest. To solve this problem we extended the detection method by also taking into account the first-order derivatives (edges).To evaluate our approach we acquired slabbed MIP images from clinical multislice-CTA data sets of four patients with increasing degree of carotid artery stenosis. In these images the CLL of the internal and external carotid arteries (for a total of eight CLLs) were traced: 1) manually (as a reference), 2) automated, based on ridge detection (as described in the literature), and 3) automated, using our extended method based on a combination of ridge and edge detection. All tracings were given the same start and end point in the vessels. To measure the accuracy of the automated tracings, we calculated the average deviation with respect to their corresponding reference tracings. The statistical significance of the difference between the two automated methods was determined by means of a paired Student t-test.
Results: Visual assessment showed that the ridge detection technique produced two correct CLLs. Our combination technique produced seven correct CLLs, leaving one case where the tracing partly followed the internal instead of the desired external carotid. Calculation of the average deviation showed that the combination technique clearly outperformed the ridge detection technique with an average error of approximately tenfold smaller. The difference in accuracy between the two automated tracing techniques was found to be statistically significant (p < 0.05).
Conclusion: The combination of edge and ridge information results in increased accuracy in the automated tracing of the CLL in carotid arteries. These tracings appear accurate enough to serve as a basis for automated measurements.
Copyright © 2003 the authors. Published version © 2003 Nederlandse Vereniging voor Radiologie. Personal use of this material is permitted. However, permission to reprint or republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works, must be obtained from the copyright holder.